Attribute: KONZ = [Unit depends on the type of transport calculation.] (transport model only)
KONZ assigns concentration/temperature values to defined inflows (defined by KNOT, FLAE, RAND, RANQ, RANX) and computed inflows (leakage rates, mass flow rates at fixed potential heads). Inflow rates without any concentration specified have automatically the default concentration 0. The concentration is always assigned to nodes. The boundary condition KONZ can be defined as transient boundary condition as well (transient data KONZ).